Product description
- Emergency lighting LED driver with DALI-2 interface and automatic test function
-
- For self-contained emergency lighting
-
- For LED modules with a forward voltage of 10 – 54 V
-
- SELV for output voltage < 60 V DC
-
- Strain relief
-
- Compatible with Tridonic s LLE FLEX modules (ADV, EXC)
-
- EM = Emergency
-
- Nominal lifetime up to 100,000 h
-
- 5 years guarantee (conditions at
-
Common Data
Rated supply voltage
220 – 240 V
AC voltage range
198 – 264 V
Forward voltage range LED module
10 – 54 V
Mains frequency
50 60 Hz
Overvoltage protection
320 V (for 48 h)
Output current
Refer to EM converterLED BASIC data sheet
Starting time
< 0.5 s from detection of emergency event
U-OUT (including open- short-circuit and double load)
60 V
Max. open circuit voltage
60.0 V
Mains voltage changeover threshold
According to EN 60598-2-22
Mains surge capability (between L – N)
1 kV
Mains surge capability (between L N – PE)
2 kV
Rest mode max. number of emergency units
100.0
Rest mode max. wiring distance
1000.0 m
Functional test
Weekly 5s test
Duration test
Yearly 3 h test
Guarantee
5 years
Title
Default Title
Review Cart
- Emergency lighting LED driver with DALI-2 interface and automatic test function
- For self-contained emergency lighting
- For LED modules with a forward voltage of 10 – 54 V
- SELV for output voltage < 60 V DC
- Strain relief
- Compatible with Tridonic s LLE FLEX modules (ADV, EXC)
- EM = Emergency
- Nominal lifetime up to 100,000 h
- 5 years guarantee (conditions at
Common Data
Rated supply voltage 220 – 240 V AC voltage range 198 – 264 V Forward voltage range LED module 10 – 54 V Mains frequency 50 60 Hz Overvoltage protection 320 V (for 48 h) Output current Refer to EM converterLED BASIC data sheet Starting time < 0.5 s from detection of emergency event U-OUT (including open- short-circuit and double load) 60 V Max. open circuit voltage 60.0 V Mains voltage changeover threshold According to EN 60598-2-22 Mains surge capability (between L – N) 1 kV Mains surge capability (between L N – PE) 2 kV Rest mode max. number of emergency units 100.0 Rest mode max. wiring distance 1000.0 m Functional test Weekly 5s test Duration test Yearly 3 h test Guarantee 5 years Title Default Title
Review Cart